This manual provides essential guidance for operating the Respironics Trilogy Evo ventilator․ It details features, safety protocols, and troubleshooting steps for optimal device performance․
Gmail offers versatile communication, including video chat and voice calls, all within your inbox․ It’s accessible across devices, ensuring constant connectivity․
Philips Respironics prioritizes patient safety, addressing recalls related to sound abatement foam and providing robust service tools for diagnostics and upgrades․
What is the Trilogy Evo?
The Trilogy Evo is a sophisticated, yet user-friendly, ventilator designed for both invasive and non-invasive respiratory support․ It caters to a broad spectrum of patient needs, offering versatile ventilation modes like CPAP, Spontaneous/Timed, and Volume Control․
This device, manufactured by Philips Respironics, integrates advanced features like a ramp function and adjustable trigger sensitivity․ It’s built for reliability and ease of use, supported by comprehensive service tools and diagnostic capabilities, ensuring optimal patient care․
Scope of this Manual
This manual comprehensively covers the Respironics Trilogy Evo ventilator, encompassing setup, operation, maintenance, and troubleshooting․ It details the user interface, alarm systems, and advanced customization options․
Furthermore, it provides guidance on accessing the service tool, interpreting diagnostic tests, and understanding event codes․ This resource is intended for clinicians and healthcare professionals responsible for the device’s safe and effective use, ensuring optimal patient outcomes․

Setting Up Your Trilogy Evo
Proper setup involves unboxing, connecting power and accessories, and completing initial configuration․ Ensure a thorough inspection before use, following the guidelines provided herein․
Unboxing and Initial Inspection
Carefully unpack the Trilogy Evo, verifying all components are present according to the packing list․ Inspect the device for any visible damage incurred during shipping, including cracks or dents․ Check accessories – tubing, power cord, and filters – for integrity․
Confirm the device operates correctly after initial power-on․ Document any discrepancies immediately and contact Philips Respironics support․ Retain all packaging materials for potential returns or servicing․
Connecting to Power and Accessories
Connect the provided power cord to the Trilogy Evo and a grounded electrical outlet, ensuring proper voltage․ Attach the patient circuit tubing, verifying secure connections․ Connect any optional accessories, such as a humidifier or external monitor, following their respective manuals․
Confirm all connections are firm and secure before initiating operation․ Utilize only Philips-approved accessories to maintain device performance and safety standards․
Initial Device Configuration
Power on the Trilogy Evo and follow the on-screen prompts to set the date, time, and language․ Configure basic ventilator settings, including patient profile and initial ventilation mode, as prescribed by a physician․ Establish network connectivity for data transfer and remote monitoring․
Complete a self-test to verify proper functionality․ Ensure all settings align with the patient’s needs and clinical protocols before initiating therapy․

Understanding the User Interface
The Trilogy Evo features an intuitive display with clear icons and menus․ Navigation is streamlined for quick access to settings and patient data, enhancing usability․
Display Overview
The Trilogy Evo’s display presents vital ventilation parameters, including pressure, volume, and respiratory rate, in a clear, organized format․ Alarm indicators provide immediate alerts to potential issues․ Users can easily monitor patient status and adjust settings via the touchscreen interface․ Key data is readily visible, supporting informed clinical decisions․ The interface allows for customization of displayed information, tailoring it to individual needs and preferences for efficient monitoring․
Navigation and Controls
The Trilogy Evo utilizes an intuitive touchscreen interface for seamless navigation․ Users can access menus, adjust settings, and review data with simple taps and swipes․ Dedicated control buttons offer quick access to frequently used functions․ The service tool, accessible via a PC connection, enables advanced diagnostics and software updates․ This streamlined control system enhances usability and efficiency for healthcare professionals․
Alarm System and Indicators
The Trilogy Evo features a comprehensive alarm system with visual and audible alerts․ These indicators signal critical events, such as high/low pressure, apnea, or power failure․ Event codes, detailed within the service manual, provide specific troubleshooting guidance․ Prioritizing patient safety, the system ensures prompt response to any deviations from prescribed settings, facilitating timely intervention․
Ventilation Modes
The Trilogy Evo supports diverse modes like CPAP/S, Spontaneous/Timed, and Volume Control․ These options allow clinicians to tailor ventilation to individual patient needs and respiratory patterns․
CPAP/S Mode
CPAP/S mode delivers continuous positive airway pressure, maintaining airway patency during spontaneous breathing․ This setting is ideal for patients requiring support to overcome upper airway obstruction or mild respiratory distress․ The Trilogy Evo allows adjustment of CPAP levels to optimize patient comfort and effectiveness․
Supplemental oxygen can be administered concurrently․ Careful monitoring of the patient’s respiratory rate and effort is crucial when utilizing CPAP/S, ensuring adequate ventilation and avoiding over-assistance․
Spontaneous/Timed Mode
Spontaneous/Timed (S/T) mode combines patient-triggered breaths with time-cycled breaths, offering a balance of control and support․ The Trilogy Evo delivers a set tidal volume or pressure at a pre-defined rate if the patient fails to initiate a breath within the set backup rate․
This mode is suitable for patients needing partial ventilatory assistance, promoting spontaneous breathing while ensuring adequate minute ventilation․ Adjusting parameters like tidal volume and backup rate is key․
Volume Control Mode
Volume Control (VC) mode on the Trilogy Evo delivers a pre-set tidal volume with each breath, regardless of patient effort․ The device adjusts inspiratory time to achieve the set volume, maintaining consistent ventilation․ This mode is ideal for patients requiring a guaranteed minute volume․
Careful monitoring of airway pressures is crucial in VC mode to prevent barotrauma․ Adjustments to respiratory rate and tidal volume are made based on patient needs․

Advanced Settings and Customization
The Trilogy Evo allows personalized ventilation through adjustable parameters like ramp time, trigger sensitivity, and expiratory time control, optimizing patient comfort and therapy․
Ramp Feature Configuration
The Ramp feature on the Trilogy Evo gradually increases pressure during the initial minutes of therapy, enhancing patient comfort and acceptance․ Users can customize the ramp duration, typically ranging from one to sixty minutes, tailoring it to individual needs․
Proper configuration minimizes discomfort associated with sudden pressure changes, promoting smoother transitions to the prescribed ventilation settings․ Adjustments are made via the device’s user interface, ensuring precise control over the ramp profile․
Trigger Sensitivity Adjustment
Trigger sensitivity on the Trilogy Evo dictates how readily the device responds to patient inspiratory efforts․ Adjusting this setting optimizes synchronization between the ventilator and the patient’s breathing pattern; Lower sensitivity requires stronger efforts, while higher sensitivity detects even subtle attempts․
Fine-tuning this parameter minimizes work of breathing and ensures effective ventilation․ Careful consideration of patient condition and clinical assessment is crucial for optimal trigger sensitivity configuration․
Expiratory Time Control
Expiratory Time Control (ETC) on the Trilogy Evo manages the duration of the expiratory phase during ventilation․ Adjusting ETC influences gas exchange and prevents air trapping, particularly in patients with obstructive lung disease․ Shorter ETCs may lead to incomplete exhalation, while longer ETCs can increase auto-PEEP․
Clinical assessment and monitoring of ETCO2 are vital when modifying ETC settings to ensure optimal ventilation and minimize respiratory compromise․

Troubleshooting Common Issues
This section details solutions for frequent Trilogy Evo problems, including alarm resolution, connectivity issues, and power failures, ensuring continued, safe operation․
Event codes and corrective actions are outlined for efficient diagnostics and maintenance, maximizing device uptime․
Alarm Resolution Guide
This guide provides a systematic approach to resolving Trilogy Evo alarms․ Prioritize patient assessment before addressing the alarm itself․ Common alarms include high/low pressure, apnea, and circuit disconnect․
Refer to the Trilogy Evo event codes list for specific troubleshooting steps․ Ensure proper connections, check for obstructions, and verify settings․ If alarms persist, consult the full service manual or Philips Respironics support․
Always document alarm occurrences and resolutions for future reference and improved patient care․
Connectivity Problems
Troubleshooting connectivity issues on the Trilogy Evo involves verifying cable connections and network settings․ Ensure the device is within range of the network and that the correct IP address is configured․
Check firewall settings that may be blocking communication․ Utilize the service tool for diagnostic tests to pinpoint the source of the problem․ Restarting the device and network equipment can often resolve temporary glitches․
Refer to Philips Respironics support for advanced assistance․
Device Not Powering On
If the Trilogy Evo fails to power on, first verify the power cord is securely connected to both the device and a functioning power outlet․ Check the fuse within the power supply for any signs of damage or failure․
Attempt a battery test using the service tool to assess battery health․ If using AC power, confirm the adapter is delivering the correct voltage․ Contact Philips Respironics support if issues persist․

Performing Routine Maintenance
Regular cleaning, filter replacements, and software updates are crucial for maintaining Trilogy Evo performance and ensuring patient safety․ Follow guidelines carefully․
Gmail provides secure email access across devices, while Philips Respironics focuses on ventilator reliability through diligent maintenance procedures․
Cleaning and Disinfection
Routine cleaning of the Trilogy Evo is vital to prevent healthcare-associated infections․ Utilize approved disinfectants, following Philips Respironics’ guidelines for concentration and contact time․ Always disconnect the device from power and accessories before cleaning․ Pay close attention to patient-contact surfaces, including the ventilator tubing and humidifier chamber․
Ensure thorough drying before reconnecting․ Gmail’s security features protect your data, mirroring the importance of a clean and well-maintained ventilator for patient well-being․
Refer to the full manual for a comprehensive list of compatible cleaning agents․
Filter Replacement
Regular filter replacement maintains optimal Trilogy Evo performance and air quality․ Inspect filters routinely, replacing them according to the schedule outlined in the manual – typically every six months, or more frequently in dusty environments․ Use only Philips-approved replacement filters to ensure compatibility and efficacy․
Disconnect the device from power before accessing the filter compartment․ Gmail’s reliable service parallels the need for consistent filter changes for uninterrupted ventilation․
Proper disposal of used filters is essential; follow local regulations․
Software Updates and Upgrades
Periodically check for Trilogy Evo software updates via the Philips Respironics website or through the device’s interface․ Updates enhance functionality, improve performance, and address potential security vulnerabilities․ Follow the on-screen prompts carefully during the upgrade process, ensuring a stable power supply․
Interruptions during updates can cause errors, potentially requiring a firmware restore․ Gmail’s continuous improvements mirror the importance of keeping your Trilogy Evo current․
Refer to the service manual for detailed instructions and troubleshooting․

Service Tool and Diagnostics
The Trilogy Evo’s service tool enables diagnostic tests and access to event codes․ Utilize it for troubleshooting and corrective actions, as outlined in the manual․
Accessing the Service Tool
To access the Trilogy Evo service tool, create a dedicated folder on your service PC, naming it “Trilogy Evo/EV300 Service Diagnostic and Test Tool”․ Ensure your device is connected․ From the product tree within the tool, carefully select the appropriate device model․
This allows technicians to perform comprehensive diagnostics, run tests, and interpret event codes for effective troubleshooting and maintenance of the ventilator system, ensuring optimal performance․
Diagnostic Tests
The Trilogy Evo service tool facilitates a range of diagnostic tests․ These tests assess critical ventilator functions, including sensor accuracy, motor performance, and alarm system responsiveness․ Technicians can evaluate software integrity and identify potential hardware failures․
Successful completion of these tests confirms the device operates within specified parameters, ensuring reliable and safe patient ventilation․ Detailed results aid in targeted repairs and preventative maintenance․
Event Codes and Corrective Actions
The Trilogy Evo generates specific event codes to indicate system anomalies․ These codes, detailed within the service tool, pinpoint the nature of the issue – from sensor malfunctions to software errors․
Corresponding corrective actions are provided for each code, guiding technicians through troubleshooting steps․ This structured approach minimizes downtime and ensures efficient repairs, maintaining optimal ventilator functionality and patient safety․
Safety Precautions
Prioritize electrical and patient safety during operation․ Adhere to environmental guidelines for proper device function and longevity, ensuring responsible usage of the Trilogy Evo․
Electrical Safety
Ensure the Trilogy Evo is properly grounded to prevent electrical shock․ Regularly inspect power cords for damage, replacing them immediately if frayed or compromised․ Avoid using the device near water or flammable materials․ Only utilize approved power sources matching the device’s specifications․ Disconnect the ventilator during cleaning and maintenance to eliminate electrical hazards․
Never attempt to open or modify the internal electrical components, as this could create a dangerous situation and void the warranty․ Report any electrical malfunctions to qualified service personnel promptly․
Patient Safety
Always adhere to prescribed ventilation settings and monitor the patient closely for any adverse reactions․ Ensure proper alarm settings are configured to alert caregivers to critical changes in patient condition․ Regularly inspect the patient’s skin for pressure ulcers caused by interfaces․
Confirm secure connections of all tubing and accessories to prevent disconnections․ Utilize appropriate patient assessment protocols and promptly address any clinical concerns․ Prioritize patient comfort and safety throughout ventilation therapy․
Environmental Considerations
Dispose of used filters, tubing, and other disposable components in accordance with local regulations for medical waste․ Minimize energy consumption by utilizing the device’s power-saving features when appropriate․ Properly recycle packaging materials whenever possible to reduce environmental impact․
Avoid operating the device in excessively dusty or humid environments․ Ensure responsible handling of electronic components to prevent environmental contamination․ Follow Philips Respironics guidelines for sustainable practices․
Technical Specifications
The Trilogy Evo features specific dimensions, weight, and power requirements․ It operates within defined environmental parameters, ensuring reliable performance across various clinical settings․
Dimensions and Weight
The Trilogy Evo ventilator is designed for portability and ease of use․ Precise dimensions are crucial for placement within various healthcare environments․ While specific figures require referencing the official documentation, the device is generally compact․
Weight considerations are also important for transportation and mounting․ The Trilogy Evo aims to balance robust functionality with a manageable weight, facilitating efficient workflow for clinicians and caregivers․ Detailed specifications are available in the full manual․
Power Requirements
The Trilogy Evo ventilator operates on standard AC power, typically 100-240V at 50/60Hz, ensuring compatibility across diverse electrical systems․ It also features integrated battery power for uninterrupted operation during transport or power outages․
Battery life varies depending on settings and usage․ Proper charging protocols, detailed in the manual, are essential for maintaining optimal battery performance and ensuring continuous ventilation support for patients․
Operating Environment
The Trilogy Evo is designed for use in a variety of healthcare settings, including hospitals, clinics, and patient homes․ Optimal operating temperature ranges from 10°C to 40°C (50°F to 104°F)․
Humidity should be maintained between 15% and 95%, non-condensing․ Avoid direct sunlight, excessive dust, and exposure to flammable materials to ensure reliable performance and longevity of the device․

Frequently Asked Questions (FAQ)
This section addresses common user inquiries regarding battery life, data management, and compatibility with external devices, ensuring a smooth user experience with Trilogy Evo․
Battery Life and Charging
The Trilogy Evo’s battery performance varies based on settings and usage․ Expect several hours of operation on a fully charged battery, suitable for transport or power outages․
Charging typically takes several hours using the provided power adapter․ Regularly check the battery status indicator on the device’s display to ensure optimal power availability․
Avoid extreme temperatures during charging, and follow the recommended charging cycles outlined in the full user manual for longevity․
Data Storage and Transfer
The Trilogy Evo stores ventilation data, including event logs and therapy parameters, for review and analysis․ This data is crucial for tracking patient progress and optimizing treatment plans․
Data transfer can be achieved via a USB connection to a computer, allowing clinicians to download information for reporting or integration with electronic health record systems․
Ensure data security protocols are followed during transfer, and refer to the manual for compatible software and file formats;
Compatibility with Other Devices
The Trilogy Evo is designed to integrate with select hospital monitoring systems and data management platforms, facilitating seamless data exchange for comprehensive patient care․
Compatibility extends to certain pulse oximeters and other respiratory monitoring tools, enhancing the overall clinical picture․ Verify specific device compatibility
before connection to ensure accurate data transmission and avoid potential interference․ Refer to the manual’s compatibility list for detailed information․

Warranty Information
The Trilogy Evo warranty covers defects in materials and workmanship․ Coverage details, claim processes, and limitations are outlined within this manual for your review․
Coverage Details
The Trilogy Evo’s warranty typically covers manufacturing defects for a specified period, often one to two years from the original purchase date․ This includes component failures under normal use․ The warranty does not cover damage from misuse, accidents, unauthorized repairs, or normal wear and tear․ Accessories may have separate, shorter warranty periods․ Proof of purchase is required for all claims, and Philips Respironics reserves the right to inspect the device before authorizing repair or replacement․
Claim Process
To initiate a warranty claim for your Trilogy Evo, contact Philips Respironics Support directly․ You’ll need your device serial number, proof of purchase, and a detailed description of the issue․ Philips may request you to return the device for inspection․ Approved claims will result in repair or replacement, at Philips’ discretion․ Shipping costs may apply, and Philips will provide further instructions throughout the process․

Contact Information
For support, reach Philips Respironics directly․ Locate Service Centers through their website or by calling their support line for assistance with your Trilogy Evo․
Philips Respironics Support
Philips Respironics offers comprehensive support for the Trilogy Evo․ Users can access assistance through their official website, which provides FAQs, troubleshooting guides, and downloadable resources․ Direct contact is available via phone for immediate support needs, and a network of authorized Service Centers ensures convenient repairs and maintenance․
Their dedicated team is equipped to address technical issues, warranty claims, and general inquiries, ensuring optimal ventilator performance and patient care․ Explore their online portal for detailed information․
Service Centers
Philips Respironics maintains a widespread network of authorized Service Centers globally, providing expert repair and maintenance for the Trilogy Evo ventilator․ These centers employ certified technicians trained to diagnose and resolve technical issues efficiently․
Locate the nearest center through the Philips Respironics website using their Service Locator tool․ They offer preventative maintenance, calibration, and repair services, ensuring continued reliable performance of your device and adherence to safety standards․